Products
Article number | 033-9-0023 |
Operating principle | Non-dispersive infrared (NDIR) |
Measured gas | CO₂ |
Measurement range | 0 to 10%vol |
Accuracy | ±0.3%vol CO2 ±3% of measured value |
Operating range RH | <95 % RH |
Operation range °C | <50 °C |
Warm-up time | ≤1 min |
Response time | <20 sec |
Power supply | VDC max rating, stabilized to within 10% |
Peak current | 250 mA |
Average current | 40 mA |
Communication | I2C, UART |
Outputs |
1x Analogue 1x Digital |
Compliance | TBA |
Maintenance | Zero/background calibration |
Life expectancy | >15 years |
Dimensions | 51 x 57 x 14 mm (L x W x H) |
Weight | TBA |
Storage conditions | 0-50 °C |
033-9-0026 | Senseair ICB 30% | PWM (pulse width modulation) output, linear 0 to 5 V |
033-9-0027 | Senseair ICB-F 30% | PWM (pulse width modulation) output, linear 0 to 5 V, tube in/out (gas sampling). |
033-9-0023 | Senseair ICB-F 10% | PWM (pulse width modulation) output, linear 0 to 5 V. Tube in/out (gas sampling) |
K33 ICB F
Technical Description
Article number | Product | Description |
Evaluation kit / SADK | For bio applications with range up to 10%. |